Chauvet Strike 1
Preliminary Information
Batteries None
Mounting Technology Through Hole, SMD, BGA, Sockets
Capacitor Types Aluminum Electrolytic, Tantalum, Ceramic, Polymer
Destructive Entry No

This is a template page for creating new pages for devices, troubleshooting them, part lists, and other repair info.

Known Issues

Symptom or Problem Encountered

Non functioning light. No display on the control panel.

I was told it's the PSU. It wasn't.

Causes

  • Shorted diode on controller board.

Solutions

  • Replace a £0.60 diode.

Disassembly Notes

These are outdoor lights and the cap head screws may have corrosion in the aluminium housing. Use penetrating oil if possible. Remove the three cap head screws holding the display and control panel housing.

Controller board showing faulty diode.

Diagnosis

Without power connected check for a short across D2, adjacent to the inductor.

If short, lift one side of the diode (or remove it completely) and check the diode and the solder pads. In my case the short on the board went away.

NB: The voltage to the board is 63V DC.

Replacing the diode fixed the fault. But As to what caused the failure in the first place?

I repaired two of these with identical faults.

Original Parts

Basic PCB Name

Controller board.

Diode Specifications and Footprint Information
RefDes Qty Voltage Current Mount Diameter/Size Height Temp Type
SS310 1 100 3A SMD DO214 0 °C

Replacement Parts

Basic PCB Name

Diode
RefDes Qty Compatible Part Number Order Links
1

If parts are not available or different selection is preferred, you can use the values in the Original Parts section to perform a parametric search.

References