Chauvet Strike 1: Difference between revisions
Millstream (talk | contribs) m (Update) |
Millstream (talk | contribs) mNo edit summary |
||
Line 35: | Line 35: | ||
==Original Parts== | ==Original Parts== | ||
===Basic PCB Name=== | ===Basic PCB Name=== | ||
Controller board. | |||
{| class="wikitable sortable" | {| class="wikitable sortable" | ||
|+Diode [[Capacitor Specifications|Specifications]] and [[Part Footprints|Footprint]] Information | |+Diode [[Capacitor Specifications|Specifications]] and [[Part Footprints|Footprint]] Information | ||
Line 53: | Line 53: | ||
|3A | |3A | ||
|SMD | |SMD | ||
| | |DO214 | ||
| | | | ||
|0 °C | |0 °C |
Revision as of 07:41, 15 July 2023
- For more information, see this article's corresponding Wikipedia page: Device.
Preliminary Information | |
---|---|
Batteries | None |
Mounting Technology | Through Hole, SMD, BGA, Sockets |
Capacitor Types | Aluminum Electrolytic, Tantalum, Ceramic, Polymer |
Destructive Entry | No |
This is a template page for creating new pages for devices, troubleshooting them, part lists, and other repair info.
Known Issues
Symptom or Problem Encountered
Non functioning light. No display on the control panel.
I was told it's the PSU. It wasn't.
Causes
- Shorted diode on controller board.
Solutions
- Replace a £0.60 diode.
Disassembly Notes
These are outdoor lights and the cap head screws may have corrosion in the aluminium housing. Use penetrating oil if possible. Remove the three cap head screws holding the display and control panel housing.
Diagnosis
Without power connected check for a short across D2, adjacent to the inductor.
If short, lift one side of the diode (or remove it completely) and check the diode and the solder pads. In my case the short on the board went away.
NB: The voltage to the board is 63V DC.
Replacing the diode fixed the fault. But As to what caused the failure in the first place?
I repaired two of these with identical faults.
Original Parts
Basic PCB Name
Controller board.
RefDes | Qty | Voltage | Current | Mount | Diameter/Size | Height | Temp | Type |
---|---|---|---|---|---|---|---|---|
SS310 | 1 | 100 | 3A | SMD | DO214 | 0 °C |
Replacement Parts
Basic PCB Name
RefDes | Qty | Compatible Part Number | Order Links |
---|---|---|---|
1 |
If parts are not available or different selection is preferred, you can use the values in the Original Parts section to perform a parametric search.