Mains Power: Difference between revisions

From Caps Wiki
Jump to navigation Jump to search
(Created page with "Mains power refers to the AC power at the final stage of the electrical grid that is run into buildings. In the US the standards is approximately 120VAC and in areas of Europe approximately 240VAC. There is significant danger in coming into contact with mains power as unlike most devices the only limit to the current is a breaker or fuse in the service box for the building. As such devices with exposed mains power have inherent hazards when they are powered. == Live or...")
 
mNo edit summary
Line 9: Line 9:
== Filter Caps ==
== Filter Caps ==
In older DC power supplies it is common to add bulk capacitance to the rectified input voltage from the AC source. These capacitors may be charged up to the level of the AC mains voltage and depending on the design of the power supply may hold that charge after the device has been turned off. If working on a power supply it may be advisable to use a bleeder resistor connection to discharge these capacitors in a controlled manner to avoid the shock hazard.
In older DC power supplies it is common to add bulk capacitance to the rectified input voltage from the AC source. These capacitors may be charged up to the level of the AC mains voltage and depending on the design of the power supply may hold that charge after the device has been turned off. If working on a power supply it may be advisable to use a bleeder resistor connection to discharge these capacitors in a controlled manner to avoid the shock hazard.
[[Category:General Guides]]

Revision as of 18:12, 8 February 2022

Mains power refers to the AC power at the final stage of the electrical grid that is run into buildings. In the US the standards is approximately 120VAC and in areas of Europe approximately 240VAC. There is significant danger in coming into contact with mains power as unlike most devices the only limit to the current is a breaker or fuse in the service box for the building. As such devices with exposed mains power have inherent hazards when they are powered.

Live or Hot Chassis

Some devices such as CRT displays or televisions or radios may have been designed with a live chassis that is connected to mains power. This means touching the chassis while having contact with either neutral or earth ground can complete a circuit and result in a significant electrical shock. These also pose a hazard for diagnostics and can lead to other difficulties such as finding a suitable DC ground reference for taking measurements.


TODO - Document methods of determining a live chassis in an unpowered state.

Filter Caps

In older DC power supplies it is common to add bulk capacitance to the rectified input voltage from the AC source. These capacitors may be charged up to the level of the AC mains voltage and depending on the design of the power supply may hold that charge after the device has been turned off. If working on a power supply it may be advisable to use a bleeder resistor connection to discharge these capacitors in a controlled manner to avoid the shock hazard.