Line 16: | Line 16: | ||
**Identified ruptured vents on C305 and C306<ref>https://www.youtube.com/watch?v=qJ1T8Fk9Jz4</ref> | **Identified ruptured vents on C305 and C306<ref>https://www.youtube.com/watch?v=qJ1T8Fk9Jz4</ref> | ||
***Solution: Recap | ***Solution: Recap | ||
== Disassembly Notes == | |||
Wires for most of the connectors are directly soldered to the main PCB making it practically impossible to work on without desoldering wires. Specifically the wires for the AC power connector run under some parts and are soldered on both ends making it difficult to remove the PCB. You should get the board out as much as possible and desolder the wires from the PCB to get better access to it. | |||
==Original Parts== | ==Original Parts== |
Revision as of 02:27, 18 January 2022
Preliminary Information | |
---|---|
Release Year | 2004 |
Leak Risk | Low |
Mounting Technology | Through Hole |
Capacitor Types | Aluminum Electrolytic |
Destructive Entry | No |
The XConnect by Ultra was the world's first fully modular power supply for a computer. Ultra is not a particularly well respected brand though and even when it was new the power supply was known to have issues.
Known Issues
- Other
- Identified ruptured vents on C305 and C306[1]
- Solution: Recap
- Identified ruptured vents on C305 and C306[1]
Disassembly Notes
Wires for most of the connectors are directly soldered to the main PCB making it practically impossible to work on without desoldering wires. Specifically the wires for the AC power connector run under some parts and are soldered on both ends making it difficult to remove the PCB. You should get the board out as much as possible and desolder the wires from the PCB to get better access to it.
Original Parts
RefDes | Qty | Capacitance | Voltage | Mount | Diameter | Temp | Brand | Series |
---|---|---|---|---|---|---|---|---|
C305, C306 | 2 | 3300uF | 10V | Through Hole | 10mm | 105C | Fuhjyyu | TNR |
C304 | 1 | 2.2uF | 50V | Through Hole | 5mm | 105C | Fuhjyyu | TNR |
C307 | 1 | 70uF | 10V | Through Hole | 8mm | 105C | Fuhjyyu | TNR |
C308, C309 | 1 | 3300uF | 16V | Through Hole | 13mm | 105C | Fuhjyyu | TNR |
C310, C311, C3XX? | 3 | 470uF | 15V | Through Hole | 8mm | 105C | Fuhjyyu | TNR |
C312 | 1 | 1000uF | 10V | Through Hole | 8mm | 105C | Fuhjyyu | TNR |
C313 | 1 | 2200uF | 10V | Through Hole | 10mm | 105C | Fuhjyyu | TN |
C214, C107, C108 | 3 | 10uF | 50V | Through Hole | 5mm | 105C | Fuhjyyu | TN |
C209, C204 | 2 | 1uF | 50V | Through Hole | 5mm | 105C | Fuhjyyu | TN |
C210 | 1 | 2.2uF | 50V | Through Hole | 5mm | 105C | Fuhjyyu | TN |
C208?, C201 | 2 | 4.7uF | 50V | Through Hole | 5mm | 105C | Fuhjyyu | TN |
C202 | 1 | 47uF | 50V | Through Hole | 6mm | 105C | Fuhjyyu | TN |
C102, C103 | 2 | 1000uF | 200V | Through Hole | 25mm | 85C | CapXon | NEG |
Replacement Parts
TODO
RefDes | Qty | Preferred Part | Distributor Links
[ Preferred / Search ] | |||||
---|---|---|---|---|---|---|---|---|
Digikey | Mouser | Farnell | ||||||
Part | 🔎 | Part | 🔎 | Part | 🔎 | |||
Full Parts BOM | BOM | BOM | [https://uk.farnell.com BOM[ |
If parts are not available or different selection is preferred, you can use the values in the Original Parts section to perform a parametric search.