Several dipped tantalum through hole style capacitors which have failed short circuit causing damage to a number of upstream regulation components including the resistors upper right used in a Zener diode shunt regulator. Capacitors removed from a Heathkit oscilloscope.
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 01:32, 19 January 2022 | 3,503 × 1,971 (4.7 MB) | WizardTim (talk | contribs) | Several dipped tantalum through hole style capacitors which have failed short circuit causing damage to a number of upstream regulation components including the resistors upper right used in a Zener diode shunt regulator. Capacitors removed from a Heathkit oscilloscope. |